Search
Click image to enlarge
Systems

POSITIONAL MASS FLOW CONTROLLER (GFC X )

Series Outline

Based on Pivotal’s proprietary position control valve and fild proven robust design, we are introducing high-performance and economical gas flow controller.

SERIES FEATURES

Wide Flow Range:
Full Scale 2.0−100%
Flow Accuracy:
±1.0% of Setpoint for 10% -100% Full Scale
±0.25% of full scale for 2.0−10.0% Full Scale
Fastest Settling Time for Turn-On and Turndown:
3100ms: 00ms:0.5 100% Full Scale % -10% Full Scale
Fastest Settling Time for Turn-On and Turndown:
≤300ms 10% - 100% F.S.
Automated In Situ Calibration
NIST Traceable
Innovative Control Technology:
Robust Design, No Orifice

BENEFITS

Wide Flow Range:
Full Scale 2.0−100%
Flow Accuracy:
±1.0% of Setpoint for 10% -100% Full Scale
±0.25% of full scale for 2.0−10.0% Full Scale
Fastest Settling Time for Turn-On and Turndown:
3100ms: 00ms:0.5 100% Full Scale % -10% Full Scale
Fastest Settling Time for Turn-On and Turndown:
≤300ms 10% - 100% F.S.
Automated In Situ Calibration
NIST Traceable
Innovative Control Technology:
Robust Design, No Orifice

Applications

Excellent flow accuracy, wide flow range, and fast settlign time for higher flow. Downstream position control valve ensures fast step down.

Series Specifications

Performance

Flow range
0.1 - 2000 sccm (4 part numbers to cover this range)
Flow Accuracy
±0.5% of Setpoint for actual gas: 0.1 - 20 sccm (GFC20) 1 - 200 sccm (GFC200) 5 - 1000 sccm (GFC1000), 10 - 2000 sccm (GFC2000)
Settling Time
10% - 100% FS ≤ 100 ms, 0.5% - 10% FS ≤ 300 ms*
Leak Integrity
< 1E-9 atm.cc/sec (He)
Leak By Rate
0.01 sccm (GFC20), 0.1 sccm (GFC200), 0.5 sccm (GFC1000), 1.0 sccm (GFC2000)
Repeatability
±0.2% of setpoint for 0.5%-100% FS

Operating Conditions

Supply Pressure
Standard: 100 - 300kPaG (14.5 - 43.5 psig)
Low pressure gases C4H9F, SiH2Cl2, C3H1OSI, BCl3, C4F6, C4F6-q, C4F8, C5F8, SiCIA and WF6 the inlet pressure range can be as low as -81 kPaG (-11.7 psig) Refer to the Gas Bin Table on page 5 Et 6 for the specific ranges.
Downstream Pressure
Vacuum to 53 kPa (0 - 400 Torr)
Proof Pressure
2.07 MPaG (300 psig)
Design Pressure (Burst Pressure)
2.65 MPaG (385 psig)
Operating Temperature
Standard: 15-60°C, High Temperature: 15-70°C

Materials

Wetted Surface
316 SS per Semi F20
Surface Finish
5 pin average Ra
Seals
Metal (PCTFE - Optional)

Electrical

EtherCAT
24 VDC
DeviceNet
11 - 24 VDC, 5 W
Analog and RS-485
±15 VDC, 150 mA
In-Rush Current
<200 mA

APPLICATION

Critical Etch
CVD / Deposition
Critical Low Flow
Atomic Layer Etch
Atomic Layer Dep

Request a Consultation

"*" indicates required fields

This field is for validation purposes and should be left unchanged.